Engineering News Formula Table for a Vulcan 30C Air/Steam Hammer

Blows Per Foot of Penetration Bearing Capacity of Pile from Engineering News Formula, kips Ultimate Pile Axial Load Capacity from Gates Formula, kips
0 0
1 1.2
2 2.4
3 3.5
4 4.7
5 5.8
6 6.9 4.2
7 8 14.2
8 9.1 22.9
9 10.1 30.5
10 11.2 37.3
11 12.2 43.5
12 13.2 49.1
13 14.2 54.3
14 15.2 59.1
15 16.1 63.6
16 17.1 67.7
17 18 71.7
18 18.9 75.4
19 19.8 78.9
20 20.7 82.2
21 21.6 85.3
22 22.5 88.4
23 23.4 91.2
24 24.2 94
25 25 96.6
26 25.9 99.2
27 26.7 101.6
28 27.5 104
29 28.3 106.3
30 29 108.4
31 29.8 110.6
32 30.6 112.6
33 31.3 114.6
34 32.1 116.6
35 32.8 118.4
36 33.5 120.3
37 34.2 122
38 34.9 123.8
39 35.6 125.4
40 36.3 127.1
41 37 128.7
42 37.6 130.2
43 38.3 131.8
44 39 133.2
45 39.6 134.7
46 40.2 136.1
47 40.9 137.5
48 41.5 138.9
49 42.1 140.2
50 42.7 141.5
51 43.3 142.8
52 43.9 144.1
53 44.5 145.3
54 45.1 146.5
55 45.6 147.7
56 46.2 148.9
57 46.8 150
58 47.3 151.1
59 47.9 152.2
60 48.4 153.3
61 48.9 154.4
62 49.5 155.5
63 50 156.5
64 50.5 157.5
65 51 158.5
66 51.5 159.5
67 52 160.5
68 52.5 161.4
69 53 162.4
70 53.5 163.3
71 54 164.2
72 54.5 165.1
73 54.9 166
74 55.4 166.9
75 55.8 167.8
76 56.3 168.6
77 56.8 169.5
78 57.2 170.3
79 57.6 171.1
80 58.1 172
81 58.5 172.8
82 58.9 173.6
83 59.4 174.3
84 59.8 175.1
85 60.2 175.9
86 60.6 176.6
87 61 177.4
88 61.4 178.1
89 61.8 178.9
90 62.2 179.6
91 62.6 180.3
92 63 181
93 63.4 181.7
94 63.8 182.4
95 64.2 183.1
96 64.5 183.8
97 64.9 184.4
98 65.3 185.1
99 65.6 185.8
100 66 186.4
101 66.4 187.1
102 66.7 187.7
103 67.1 188.3
104 67.4 189
105 67.8 189.6
106 68.1 190.2
107 68.4 190.8
108 68.8 191.4
109 69.1 192
110 69.4 192.6
111 69.8 193.2
112 70.1 193.8
113 70.4 194.3
114 70.7 194.9
115 71.1 195.5
116 71.4 196
117 71.7 196.6
118 72 197.1
119 72.3 197.7
120 72.6 198.2
©2017 Pile Hammer Equipment